Page view 112
Using the VP-116 Mini Voice Privacy Unit
95
Using the VP-116 Mini Voice Privacy Unit
Introduction
The VP-116 Voice Privacy unit provides voice privacy at good voice quality. For information on the
VP-116 unit, read the manual supplied with the unit.
You can order option G849 that enables the MICOM-3 to support the VP software, so that you can
program the VP-116 unit directly from the radio.
Notes
The VP menu appears on your MICOM-3 radio only if the radio is connected to
the VP-116 before the radio is turned on.
Radio performance may be reduced when a VP unit is connected.
Specific Parameters for Privacy Operation
When the radio is turned while the VP-116 is physically connected to the MICOM-3, the radio
automatically starts using the specific parameters needed by the VP-116. For example, you can see
that when the privacy function is used, the bandwidth is set to 3.3K, instead of 2.7K in the clear
mode (operation without VP).
After you turn the radio off and disconnect the VP-116, the radio reverts to normal operation with a
2.7K filter bandwidth.
The parameter values used by the VP-116 are as follows:
Volume: Level 6
Squelch: Level 0
Sidetone: Level 0.
Squelch: OFF
BW: 3.3K filter.
Connecting/Disconnecting the VP-116 Unit
To connect the VP-116 to your MICOM-3:
1. Turn the radio off.
2. Connect the VP-116 to the 44-pin accessories connector at the back panel of your
MICOM-3, using the supplied cable.
3. Turn the radio on.
To disconnect the VP-116 from your MICOM-3:
Important
If you do not turn the radio off before disconnecting the VP-116, the radio
will continue working in the VP-116 mode, even though the unit is
disconnected.